論 




Google Scholar

  1. Third-order transfer matrix for crossed electric and magnetic fields calculated algebraically using a symbolic computation program: M. Toyoda, H. Hayashibara, T. Sakurai and T. Matsuo, Int. J. Mass Spectrom. Ion Processes, 146/147 (1995), 195-216.
  2. Third-order ion trajectory calculations of Wien filters: T. Sakurai, M. Toyoda, H. Hayashibara and T. Matsuo, Int. J. Mass Spectrom. Ion Processes, 146/147 (1995), 217-222.
  3. [紀要]イオントラップ内に蓄積した色素分子の光解離: 木村正広,豊田岐聡, 大阪大学低温センターだより, 93 (1996), 1-5.
  4. Study on Photodissociation of Molecular Ions by Using Ion Trap: M. Toyoda, M. Kimura and T. Matsuo, Genshikakukenkyu, Vol. 41, No. 2 (1996), 67-75.
  5. Measurement of Decay Lifetime of Metastable Dye Molecular Ions by Using Ion Trap: M. Toyoda, M. Kimura and T. Matsuo, J. Phys. Soc. Jpn, 66 (1997), 1321-1323.
  6. Ion Optics for Multi-turn Time-of-flight Mass Spectrometers with Variable Mass Resolution: T. Matsuo, M. Toyoda, T. Sakurai and M. Ishihara, J. Mass Spectrom., 32 (1997), 1179-1185.
  7. Computer Program "TRIO-DRAW" for IonTrajectory Calculation and Display with Application to TOF Information: M. Toyoda and T. Matsuo, Advances in Mass Spectrometry, 14 (1998), E03_3500.
  8. Ion Optics for Multi-turn Time of Flight Mass Spectrometers of Eight Figure Geometry: T. Matsuo, M. Toyoda, M. Ishihara and T. Sakurai, Advances in Mass Spectrometry, 14 (1998), B04_3510.
  9. A Space Time-of-Flight Mass Spectrometer for Exobiologically-Oriented Applications: T. Matsuo, M. Ishihara, M. Toyoda, H. Ito, S. Yamaguchi, R. Roll, H. Rosenbauer, Advances in Space Research, 23 (1999), 341-348.
  10. Computer Program "TRIO-DRAW" for Displaying Ion Trajectory and Flight Time: M. Toyoda and T. Matsuo, Nucl. Instr. and Meth. A, 427 (1999), 375-381.
  11. Perfect Spacial and Isochronous Focussing Ion Optics for Multi-turn Time of Flight Mass Spectrometer: M. Ishihara, M. Toyoda and T. Matsuo, Int. J. Mass Spectrom., 197 (2000), 179-189.
  12. Construction of a New Multi-turn Time-of-Flight Mass Spectrometer: M. Toyoda, M. Ishihara, S. Yamaguchi, H. Ito, T. Matsuo, R. Roll and H. Rosenbauer, J. Mass Spectrom., 35 (2000), 163-167.
  13. マルチターン飛行時間型質量分析計の開発: 豊田岐聡, 生産と技術, 52 (2000), 63-66.
  14. 惑星・彗星探査用質量分析計の開発: 豊田岐聡,奥村大輔,山口真一,石原盛男,交久瀬五雄,松尾武清, 遊・星・人, 9 (2000), 103-107.
  15. マルチターン飛行時間型質量分析計「MULTUM Linear plus」の開発: 豊田岐聡,奥村大輔,山口真一,石原盛男,交久瀬五雄,松尾武清, J. Mass Spectrom. Soc. Jpn., 48 (2000), 312-317.
  16. ポテンシャルリフト型イオン源の開発: 奥村大輔,公文代康祐,山口真一,豊田岐聡,石原盛男,交久瀬五雄, J. Mass Spectrom. Soc. Jpn., 48 (2000), 357-359.
  17. 惑星探査用磁場型質量分析器の開発: 杉原孝充,大竹真紀子,石原盛男,豊田岐聡,国広文夫,清水昌男, J. Mass Spectrom. Soc. Jpn., 49 (2001), 69-73.
  18. Construction of A New Compact Multi-Turn Time-of-Flight Mass Spectrometer 'MULTUM II': Morio Ishihara, Michisato Toyoda and Itsuo Katakuse, Advances in Mass Spectrometry , 15 (2001), 435-436.
  19. Investigation of A Multi-Turn Time-of-Flight Mass Spectrometer 'MULTUM Linear plus': Michisato Toyoda, Morio Ishihara, Daisuke okumura, Shin-ichi Yamaguchi and Itsuo Katakuse, Advances in Mass Spectrometry, 15 (2001), 437-438.
  20. 扇形磁場を用いた飛行時間型質量分析計の開発とクラスター分裂の観測: 冨江諭,真部善宏,榮欧樹,佐藤貴弥,豊田岐聡,市原敏雄,交久瀬五雄, J. Mass Spectrom. Soc. Jpn., 50 (2002), 213-216.
  21. 飛行時間型質量分析計のイオン源として用いるイオントラップの開発: 公文代康祐,豊田岐聡,岩本賢一,奥村大輔,石原盛男,木村正広,交久瀬五雄, J. Mass Spectrom. Soc. Jpn., 50 (2002), 217-222.
  22. A simple Multi-Turn Time of Fight Mass Spectrometer 'MULTUM II': Daisuke Okumura, Michisato Toyoda, Morio Ishihara and Itsuo Katakuse, J. Mass Spectrom. Soc. Jpn., J. Mass Spectrom. Soc. Jpn., 51 (2003), 349-353..
  23. [Special Feature] Multi-turn Time-of-Flight Mass Spectrometers with Electrostatic Sectors: Michisato Toyoda, Daisuke Okumura, Morio Ishihara and Itsuo Katakuse, J. Mass Spectrom., 38 (2003), 1125-1142.
  24. Application of a Multi-Turn Time-of-Flight Mass Spectrometer, 'MULTUM II', to organic compounds ionized by MALDI: Daisuke Okumura, Michisato Toyoda, Morio Ishihara and Itsuo Katakuse, J. Mass Spectrom., 39 (2004), 86-90.
  25. A compact sector-type multi-turn Time of Flight Mass Spectrometer 'MULTUM II': Daisuke Okumura, Michisato Toyoda, Morio Ishihara and Itsuo Katakuse, Nucl. Instr. and Meth. A, 519 (2004), 3.
  26. Development of Multi-turn Time-of-Flight Mass Spectrometers 'MULTUM Linear plus' and 'MULTUM II' : Michisato Toyoda, Daisuke Okumura, Morio Ishihara and Itsuo Katakuse, Advances in Mass Spectrometry, 16 (2004), 335-352.
  27. Ion/Molecule Reactions of Silver Cluster Cations with Crown Ethers in a Cylindrical Ion Trap: Kousuke KUMONDAI , Michisato TOYODA, Kenichi IWAMOTO, Morio ISHIHARA and Itsuo KATAKUSE, Japanese Journal of Applied Physics, 43 (2004), 7282-7286.
  28. Development of a GC-MS System with an Array Detector System for Endocrine Disruptor Analysis : Morio Ishihara, Michihisa Toyoda, Hiroki Sakae, Toshio Ichihara and Itsuo Katakuse, Environmental Sciences, 11 (2004), 15-24.
  29. A tandem time-of-flight mass spectrometer: combination of a multi-turn time-of-flight and a quadratic-field mirror : Michisato Toyoda, Anastassios E. Giannakopulos, Alex W. Colburn and Peter J. Derrick, Eur. J. Mass Spectrom., 11 (2005), 181-187.
  30. High-resolution TOF spectra obtained by the 'MULTUM II' multi-turn type TOF mass spectrometer with an EI ion source : Daisuke Okumura, Michisato Toyoda, Morio Ishihara and Itsuo Katakuse, Eur. J. Mass Spectrom., 11 (2005), 261-266.
  31. Experimental and theoretical study on gas-phase ion/molecule reactions of silver trimer cation, Ag3+, with 12-crown-4 : Kousuke Kumondai, Michisato Toyoda, Morio Ishihara, Itsuo Katakuse, Takae Takeuchi, Mai Ikeda and Kenichi Iwamoto, J. Chem. Phys., 123 (2005), 024314.
  32. Development of a miniature double focusing mass spectrograph using a focal plane detector : Masaru Nishiguchi, Michisato Toyoda, Morio Ishihara, Makiko Ohtake, Takamitsu Sugihara, Itsuo Katakuse, J. Mass Spectrom. Soc. Jpn., 54 (2006), 1-9.
  33. [解説]∞軌道で質量分解能も無限大 ー小型質量分析装置の近未来ー : Bionics, No.2 ( 2006), 48-53 .
  34. Differences between the internal energy depositions induced by collisional activation and by electron transfer of W(CO)62+ ions on collision with Ar and K targets : Shigeo Hayakawa, Akihiro Kitaguchi, and Satoko Kameoka, Michisato Toyoda and Toshio Ichihara, J. Chem. Phys., 124 (2006), 224320.
  35. マルチターン飛行時間型質量分析計のイオン像のシミュレーション: Michisato Toyoda and Masaru Nishiguchi, J. Mass Spectrom. Soc. Jpn., 55 (2007), 17-24.
  36. マルチターン飛行時間型質量分析計の開発とその応用: 豊田岐聡, J. Vac. Soc. Jpn., 50 (2007), 246-251.
  37. High-energy collision induced dissociation fragmentation pathways of peptides, probed using a multi-turn tandem time-of-flight mass spectrometer "MULTUM-TOF/TOF": Michisato Toyoda, Anastassios Giannakopulos, Alex Colburn, and Peter Derrick, Rev. Sci. Instrum.,78 (2007), 074101 .
  38. マルチターンタンデム飛行時間型質量分析計を用いたリン脂質のチャージリモートフラグメンテーション: Shuichi Shimma, Hirofumi Nagao and Michisato Toyoda, J. Mass Spectrom. Soc. Jpn., 55 (2007), 343-351.
  39. Potential crossing position in electron transfer of a doubly charged ion and an alkali metal target measured using thermometer molecule W(CO)6: Shigeo Hayakawa, Kaori Minami, Kenichi Iwamoto, Michisato Toyoda, Toshio Ichihara and Hirofumi Nagao, Int. J. Mass Spectrom., 266 (2007), 122-128.
  40. Dissociation channels of silver bromide cluster Ag2Br, silver cluster Ag3 and their ions studied by using alkali metal target: Hirofumi Nagao, Kunio Awazu, Shigeo Hayakawa, Kenichi Iwamoto, Michisato Toyoda and Toshio Ichihara, Eur. Phys. J. D, 45 (2007), 279-287.
  41. 手のひらサイズのマルチターン飛行時間型質量分析計「MULTUM-S」の製作: Toshio Ichihara, Satoshi Uchida, Morio Ishihara, Itsuo Katakuse and Michisato Toyoda, J. Mass Spectrom. Soc. Jpn., 55 (2007), 363-368.
  42. High-energy collision-induced dissociation of phosphopeptides using a multi-turn tandem time-of-flight mass spectrometer “MILTUM-TOF/TOF": Shuichi Shimma, Hirofumi Nagao, Anastassios E. Giannakopulos, Shigeo Hayakawa, Kunio Awazu and Michisato Toyoda, J. Mass Spectrom., 43 (2008), 535-537.
  43. Study of the dissociation of charge-reduced phosphopeptide formed by electron transfer from alkali metal target : Shigeo Hayakawa, Mami Hashimoto, Hirofumi Nagao, Kunio Awazu, Michisato Toyoda, Toshio Ichihara and Yasushi Shigeri, Rapid Commun. Mass Spectrom., 22 (2008), 567-572.
  44. Ion optical evaluation of a miniature double-focusing mass spectrograph: Masaru Nishiguchi, Morio Ishihara, Itsuo Katakuse, Michisato Toyoda, Eur. J. Mass Spectrom.,14 (2008), 7-15.
  45. Comparison of mass spectra of peptides in different matrices using matrix-assisted laser desorption/ionization and a multi-turn time-of-flight mass spectrometer, MULTUM-IMG: Hisanao Hazama, Hirofumi Nagao, Ren Suzuki, Michisato Toyoda, Katsuyoshi Masuda, Yasuhide Naito and Kunio Awazu, Rapid Commun. Mass Spectrom.., 22 (2008), 1461-1466.
  46. [解説]なぜリフレクトロンモードやマルチターンによって質量分解能が向上されるのか: 田中耕一,吉野健一,内藤康秀,豊田岐聡,J. Mass Spectrom. Soc. Jpn., 56 (2008), 49-54.
  47. Development of a tandem time-of-flight mass spectrometer "MULTUM-TOF/TOF" at Osaka University: Combination of a multi-turn time-of-flight mass spectrometer and a quadratic-field ion mirror: Michisato Toyoda, Anastassios E. Giannakopulos, Alex W. Colburn, Peter J. Derrick, Physics Procedia, 1 (2008), 401-411.
  48. Computer program TRIO 2.0 for calculation and visualization of ion trajectories: Masaru Nishiguchi, Michisato Toyoda, Physics Procedia, 1 (2008), 325-332.
  49. [解説]質量分析の将来展望: 豊田岐聡, The TRC News, 105 (Oct) (2008), 30-34.
  50. Construction of a Novel Stigmatic MALDI Imaging Mass Spectrometer: Hisanao Hazama, Jun Aoki, Hirofumi Nagao, Ren Suzuki, Toshio Tashima, Ken-ichi Fujii, Katsuyoshi Masuda, Kunio Awazu, Michisato Toyoda, Yasuhide Naito, Appl. Surf. Sci., 255 (2008), 1257-1263.
  51. Design of a new multi-turn ion optical system "IRIS" for a time-of-flight mass spectrometer: Masaru Nishiguchi, Yoshihiro Ueno, Michisato Toyoda, Mitsutoshi Setou, J. Mass Spectrom., 44 (2009), 594-604.
  52. Development of an ion trap/multi-turn time-of-flight mass spectrometer with potential-lift: Kenichi Iwamoto, Hirofumi Nagao and Michisato Toyoda, Eur. J. Mass Spectrom., 15 (2009), 249-260.
  53. Simulation of Ion Trajectories using the Surface-Charge Method on a Special Purpose Computer: Jun Aoki, Ayumi Kubo, Michisato Toyoda, Nucl. Instr. and Meth. A, 600 (2009), 466-470.
  54. Unimolecular and collision-induced dissociation of singly charged mono-bromide silver clusters AgxBr+ (x = 2, 4, 6, 8, 10): Hirofumi Nagao, Michisato Toyoda, Shigeo Hayakawa, Kenichi Iwamoto, Toshio Ichihara, Kazuya Kawamura and Kunio Awazu, Eur. J. Mass Spectrom., 15 (2009), 459-469.
  55. 高エネルギー電子移動解離が可能なタンデム質量分析装置の開発: 長尾博文,早川滋雄,橋本雅美,岩本賢一,豊田岐聡,茂里 康,地頭所眞美子,粟津邦男, J. Mass Spectrom. Soc. Jpn., 57 (2009), 123-132.
  56. 亜酸化窒素濃度の野外計測を可能にする可搬型高分解能マルチターン飛行時間型質量分析計の開発: 豊田岐聡,新間秀一,三木伸一, 北海道土壌肥料研究通信, 第55巻1号 (2009), 1-12.
  57. [紀要]新しいイオン光学系を採用した多重周回飛行時間型質量分析計の開発: 山口真一,古橋治,竹下建悟,出水秀明,榮欧樹,西口克,上野良弘,小河潔,吉田佳一,豊田岐聡,瀬藤光利, 島津評論 66 (1, 2), (2009), 53-59
  58. Development of Multi-turn Time-of-Flight Mass Spectrometers and Their Applications: Michisato Toyoda, Eur. J. Mass Spectrom., 16 (2010), 397-406.
  59. High-energy electron transfer dissociation using a tandem time-of-flight mass spectrometer with an electrospray ionization source: Hirofumi Nagao, Shuichi Shimma, Shigeo Hayakawa, Kunio Awazu, Michisato Toyoda, Eur. J. Mass Spectrom., 16 (2010), 551-556.
  60. High-Energy Electron Transfer Dissociation (HE-ETD) Using Alkali Metal Targets for Sequence Analysis of Post-Translational Peptides: Shigeo Hayakawa, Shinya Matsumoto, Mami Hashimoto, Kenichi Iwamoto, Hirofumi Nagao, Michisato Toyoda, Yasushi Shigeri, Michiko Tajiri and Yoshinao Wada, J. Am. Soc. Mass Spectrom., 21 (2010), 1482-1489.
  61. Development of a tandem time-of-flight mass spectrometer with an electrospray ionization ion source: Hirofumi Nagao, Shuichi Shimma, Shigeo Hayakawa, Kunio Awazu and Michisato Toyoda, J. Mass Spectrom., 45 (2010), 937-943.
  62. Miniaturized high-resolution time-of-flight mass spectrometer “MULTUM-S II” with an infinite flight path: Shuich Shimma, Hirofumi Nagao, Jun Aoki, Keiji Takahashi, Shinichi Miki and Michisato Toyoda, Anal. Chem., 82 (2010), 8456-8463.
  63. ロッド電極間に挿入した板状電極を用いたリニアイオントラップからのイオン排出方法の開発: 長尾博文,加納英朗,岩本賢一,豊田岐聡, J. Mass Spectrom. Soc. Jpn., 59 (2011), 13-17.
  64. Development of a stigmatic mass microscope using laser desorption/ionization and a multi-turn time-of-flight mass spectrometer: Hisanao Hazama, Hidetoshi Yoshimura, Jun Aoki, Hirofumi Nagao, Michisato Toyoda, Katsuyoshi Masuda, Kenichi Fujii, Toshio Tashima, Yasuhide Naito and Kunio Awazu, J. Biomed. Opt., 16 (2011), 046007.
  65. Evaluation of a delay-line detector combined with analog-to-digital converters as an ion detection system for stigmatic imaging mass spectrometry: Hidetoshi Yoshimura, Hisanao Hazama, Jun Aoki, Michisato Toyoda, Yasuhide Naito, and Kunio Awazu, Jpn. J. Appl. Phys., 50 (2011), 056701.
  66. Novel Ion Extraction Method for Imaging Mass Spectrometry: Jun Aoki, Hisanao Hazama and Michisato Toyoda, J. Mass Spectrom. Soc. Jpn., 59 (2011), 57-61.
  67. Polychlorinated biphenyls (PCBs) analysis using a miniaturized high-resolution time-of-flight mass spectrometer "MULTUM-S II": Shuichi Shimma, Shinichi Miki and Michisato Toyoda, J. Environ. Monit.,14 (2012), 1664-1670.
  68. Detailed Structural Analysis of Lipids Directly on Tissue Specimens Using a MALDI-SpiralTOF-Reflectron TOF Mass Spectrometer: Shuichi Shimma, Ayumi Kubo, Takaya Satoh and Michisato Toyoda, PLoS ONE, 7(5)(2012), e37107.
  69. Rapid sequencing of a peptide containing a single disulfide bond using high-energy collision-induced dissociation: Takuma Degawa, Shuichi Shimma and Michisato Toyoda, Eur. J. Mass Spectrom., 18 (4) (2012), 345-348.
  70. Miniaturized Mass Spectrometer in Analysis of Greenhouse Gases: The Performance and Possibilities: Shuichi Shimma and Michisato Toyoda, Greenhouse Gases - Emission, Measurement and Management, Dr Guoxiang Liu (Ed.), ISBN: 978-953-51-0323-3, InTech, Chapter 11 (2012), 235-254.
  71. 特集「月惑星探査の来たる10年:第二段階のまとめ」火星生命探査機器群提案 ー細胞,アミノ酸,メタン検出を目的としたー: 山岸明彦,吉村義隆,長沼毅,宮川厚夫,出村裕英,豊田岐聡,本多元,小林憲正,三田肇,大野宗祐,石丸亮,小林喬郎,戸野倉賢一,石上玄也,佐々木晶,宮本英昭,日本惑星科学会誌, 21 (3)(2012), 276-282
  72. [紀要]大阪大学大学院理学研究科附属基礎理学プロジェクト研究センターの設立について: 豊田岐聡,生産と技術, 64 (4), (2012), 90-93.
  73. Construction of a newly designed small-size mass spectrometer for helium isotope analysis: Toward continuous monitoring of 3He/4He ratio of natural fluids: Ken-ichi Bajo, Hirochika Sumino, Michisato Toyoda, Ryuji Okazaki, Takahito Osawa, Morio Ishihara, Itsuo Katakuse, Kenji Notsu and Keisuke Nagao, Mass Spectrometry, 1 (2012), A0009.
  74. [総説]マルチターン飛行時間型質量分析計: 豊田岐聡, 新間秀一, 青木順, 石原 盛男, J. Mass Spectrom. Soc. Jpn., 60 (6) (2012), 87-102.
  75. Mass spectrometry imaging and structural analysis of lipids directly on tissue specimens by using a spiral orbit type tandem time-of-flight mass spectrometer, SpiralTOF-TOF: Takaya Satoh, Ayumi Kubo, Shuichi Shimma, Michisato Toyoda, Mass Spectrometry,1 (2012), A0013.
  76. A Chemical Approach to Searching for Bioactive Ingredients in Cigarette Smoke: Y. Takahashi, S. Horiyama, C. Honda, K. Suwa, K. Nakamura, M. Kunitomo, S. Shimma, M. Toyoda, H. Sato, M. Shizuma and M. Takayama, Chem. Pharm. Bull., 61 (2013), 85-89.
  77. A Novel Sperm-Activating and Attracting Factor (SAAF) from the Ascidian Ascidia sydneiensis: Nobuaki Matsumori, Yuki Hiradate, Hajime Shibata, Tohru Oishi, Shuichi Shimma, Michisato Toyoda, Fumiaki Hayashi, Manabu Yoshida, Michio Murata, Masaaki Morisawa, Organic Letters, 15 (2013), 294-297.
  78. [総説]投影方式飛行時間型イメージング質量分析装置の開発: 青木順,豊田岐聡, J. Mass Spectrom. Soc. Jpn., 61 (3) (2013), 23-33.
  79. [進歩総説]オンサイトマススペクトロメトリー: 新間秀一,豊田岐聡, ぶんせき, 468 (12) (2013), 731-737.
  80. Ultra-High Mass Resolution Miniaturized Time-of-Flight Mass Spectrometer “infiTOF” for Rapid Analysis of Polychlorinated Biphenyls: Shuichi Shimma, Shinichi Miki, Robert B. Cody, Michisato Toyoda, Comprehensive Analytical Chemistry, 61 (2013), 303-323.
  81. Observation of Accumulated Metal Cation Distribution in Fish by Novel Stigmatic Imaging Time-of-Flight Mass Spectrometer: Jun Aoki, Shinichiro Ikeda and Michisato Toyoda, J. Phys. Soc. Jpn., 83(2) (2014), 023001.
  82. Separation of Isobaric Compounds Using a Spiral Orbit Type Time-of-Flight Mass Spectrometer, MALDI-SpiralTOF: Takaya Satoh, Ayumi Kubo, Hisanao Hazama, Kunio Awazu, Michisato Toyoda, Mass Spectrometry, 3 (2014), S0027.
  83. Development of a miniaturized multi-turn TOF mass spectrometer with a pulsed FAB ion source: Hirofumi Nagao, Shinichi Miki and Michisato Toyoda, Eur. J. Mass Spectrom., 20 (2014), 215–220.
  84. High-energy collision-activated and electron-transfer dissociation of gas-phase complexes of tryptophan with Na+, K+, and Ca2+: Akimasa Fujihara, Yuki Sha, Sou Matsuo, Michisato Toyoda and Shigeo Hayakawa, Eur. Phys. J. D, 68 (2014), 273-277.
  85. Real time monitoring of gases emitted from soils using the Multi-turn Time-of-Flight Mass Spectrometer "MULTUM-S II”: Takahiro Anan, Shuichi Shimma, Yo Toma, Yasuyuki Hashidoko, Ryusuke Hatano, Michisato Toyoda, Environmental Science: Processes & Impacts, 16 (2014), 2752 - 2757.
  86. Signal-to-noise performance evaluation of a new 12-bit digitizer on a time-of-flight mass spectrometer: Toshinobu Hondo, Yousuke Kawai and Michisato Toyoda, Eur. J. Mass Spectrom., 21 (2015), 13-17.
  87. Metabolomic Analysis of Gingival Crevicular Fluid Using Gas Chromatography/Mass Spectrometry: Miho Ozeki, Takenori Nozaki, Jun Aoki, Takeshi Bamba, Kirk R. Jensen, Shinya Murakami and Michisato Toyoda,Mass Spectrom. (Tokyo),5 (2016), A0047.
  88. High molecular weight organic compounds (HMW-OCs) in severe winter haze: Direct observation and insights on the formation mechanism: F.K. Duan, K.B. He, Y.L. Ma, T. Ihozaki, H. Kawasaki, R. Arakawa, S. Kitayama, K. Tujimoto, T. Huang, T. Kimoto, H. Furutani, M. Toyoda, Environmental Pollution, 218 (2016), 289–296.
  89. N-Terminal Derivatization with Structures Having High Proton Affinity for Discrimination between Leu and Ile Residues in Peptides by High-Energy Collision-Induced Dissociation: Atsushi Kitanaka, Masahiro Miyashita, Ayumi Kubo, Takaya Satoh, Michisato Toyoda, Hisashi Miyagawa, Mass Spectrometry (Tokyo), 5 (2016), A0051.
  90. High spatial resolution laser desorption/ionization mass spectrometry imaging of organic layers in an organic light-emitting diode: Yuko Tachibana, Yoji Nakajima, Tsuguhide Isemura, Kiyoshi Yamamoto, Takaya Satoh, Jun Aoki and Michisato Toyoda, Mass Spectrometry (Tokyo),5 (2016), A0052.
  91. Development on Multi-Turn TOF-SIMS with a Femto-second Laser for Post-Ionization: First Application of OPTIMA (Osaka PosT-Ionization MAss spectrometer) for Presolar SiCs:Kentaro Terada, Yosuke Kawai, Michisato Toyoda, Morio Ishihara, Jun Aoki, Hikaru Yabuta, Kohei Miya, Taichi Suwa, Takahiro Matsuda, and Ryosuke Nakamura, JPS Conf. Proc., 14 (2017), 011103.
  92. Instrumentation and Method Development for On-site Analysis of Helium Isotopes: Kirk R. Jensen, Toshinobu Hondo, Hirochika Sumino, and Michisato Toyoda, Anal. Chem., 89 (2017), 7535–7540.
  93. 大阪大学大学院理学研究科教育研究交流棟(理学J棟)の新築: 豊田岐聡, 生産と技術, 69 (4) (2017), 65-68.
  94. A new approach for accurate mass assignment on a multi-turn time-of-flight mass spectrometer: Toshinobu Hondo, Kirk R Jensen, Jun Aoki and Michisato Toyoda, Eur. J. Mass Spectrom., 23 (2017), 385-392.
  95. これまで見ることができなかったモノを観る ~独創的な質量分析装置開発とそれらを用いた応用研究~: 豊田岐聡, 生産と技術, 70 (2) (2018), 54-60.
  96. Improved quantitative dynamic range of time-of-flight mass spectrometry by simultaneously waveform-averaging and ion-counting data acquisition: Yosuke Kawai, Toshinobu Hondo, Kirk R. Jensen, Michisato Toyoda and Kentaro Terada, Journal of The American Society for Mass Spectrometry, 29 (7) (2018), 1403–1407.
  97. Development of an ion trap with a metastable atom bombardment ionization source to observe ion-molecule reactions: Kenichi Iwamoto, Hiroshi Matsubara and Michisato Toyoda, International Journal of Mass Spectrometry, 430 (2018), 80–86.
  98. High throughput isotope abundance ratio determination based on simultaneous ion counting and waveform averaging: Yosuke Kawai, Toshinobu Hondo, Jean-Luc Lehmann, Kentaro Terada and Michisato Toyoda, Nuclear Inst. and Methods in Physics Research, A, 942 (2019) 162427.

著 書

  1. マススペクトリメトリーってなあに: 明石知子,高山光男,豊田岐聡,橋本豊,平岡賢三,平山和雄, 日本質量分析学会 (株)国際文献印刷社刊, 4章,6章担当
  2. 実験化学講座 第5版 20-1 分析化学: 日本化学会 編, 9.2章担当(421-432ページ)
  3. タンパク質科学実験法2 タンパク質をみる ー構造と挙動ー: 長谷俊治,高尾敏文,高木淳一編, 化学同人, 2章担当(33-51ページ)
  4. 現代質量分析学: 高山光男,早川滋雄,瀧浪欣彦,和田芳直 編,化学同人,6章担当
  5. 【OUFCブックレットvol.8】中国の食・健康・環境の現状から導く東アジアの未来―地域研究における文理融合モデルの探求: 田中仁・思沁夫・豊田岐聡編, 2016年2月25日発行
  6. 質量分析学: 豊田岐聡 編著, 日本質量分析学会 (株)国際文献印刷社刊, 1章,2章担当, 2016年6月20日発行

特 許

  1. 特許名称:イオンビーム用像縮小レンズ系、イオンビーム用ズーム装置、及び質量分析装置

    発明者:石原盛男,豊田岐聡,交久瀬五雄

    特許出願人:財団法人新産業創造研究機構

    特許番号:特許第4009900号

    登録日:2007年9月14日

  2. 特許名称:質量分析装置(TOF/Trap)

    発明者:山口真一,島津光三,豊田岐聡,岩本賢一

    特許出願人:株式会社島津製作所

    特許番号:特許第3873867号

    登録日:2006年11月2日

  3. 特許名称:飛行時間型質量分析計

    発明者:豊田岐聡,石原盛男,田村淳

    特許出願人:日本電子株式会社

    特許番号:特許第4229732号

    登録日:2008年12月12日

  4. 特許名称:質量分析装置

    発明者:豊田岐聡,石原盛男,岩永光恭,貫名義裕

    特許出願人:日本電子株式会社

    出願番号:特願2003-193729

    出願日:2003年7月8日

    公開番号:特開2005-32476

    公開日:2005年2月3日

  5. 発明名称:質量分析計

    発明者:山口真一,石原盛男,豊田岐聡,奥村大輔

    特許出願人:株式会社島津製作所

    特許番号:特許第4182843号

    登録日:2008年9月12日

  6. 発明名称:質量分析計

    発明者:山口真一,石原盛男,豊田岐聡,奥村大輔

    特許出願人:株式会社島津製作所

    特許番号:特許第4182844号

    登録日:2008年9月12日

  7. 特許名称:質量分析装置

    発明者:山口真一,石原盛男,豊田岐聡

    特許出願人:株式会社島津製作所

    特許番号:特許第4273917号

    登録日:2009年3月13日

  8. 特許名称:質量分析計方法及び質量分析装置

    発明者:山口真一,石原盛男,豊田岐聡

    特許出願人:株式会社島津製作所

    特許番号:特許第4182853号

    登録日:2008年9月12日

  9. 特許名称:質量分析装置

    発明者:山口真一,石原盛男,豊田岐聡

    特許出願人:株式会社島津製作所

    特許番号:特許第4001100号

    登録日:2007年8月24日

  10. 特許名称:質量分析装置

    発明者:山口真一,石原盛男,豊田岐聡,奥村大輔

    特許出願人:株式会社島津製作所

    特許番号:特許第4033133号

    登録日:2007年11月2日

  11. 特許名称:飛行時間型質量分析方法及び装置

    発明者:佐藤貴弥、豊田岐聡、石原盛男

    出願者:日本電子株式会社

    優先権出願番号:特願2004-151473

    出願日:2004年5月21日

    公開番号:特開2006-12782

    公開日:2006年1月12日

  12. 特許名称:飛行時間型質量分析計

    発明者:豊田岐聡、石原盛男、岩永光恭、貫名義裕

    出願者:日本電子株式会社

    特許番号:特許第4533672号

    登録日:2010年6月18日

  13. 特許名称:イオントラップ装置

    発明者:佐藤貴弥、豊田岐聡、石原盛男,公文代康祐

    出願者:日本電子株式会社

    出願番号:特願2004-246419

    出願日:2004年8月26日

    公開番号:特開2006-66177

    公開日:2006年3月9日

  14. 特許名称:飛行時間型質量分析計

    発明者:佐藤貴弥、豊田岐聡

    特許出願人:日本電子株式会社

    特許番号:特許第4594138号

    登録日:2010年9月24日

  15. 特許名称:タンパク質の分析法、装置およびプログラム

    発明者:高橋勝利, 茂櫛薫, 豊田岐聡

    特許出願人:産総研

    特許番号:特許第4512751号

    登録日:2010年5月21日

  16. 特許名称:飛行時間型質量分析方法及び装置

    発明者:佐藤貴弥、豊田岐聡、石原盛男

    特許出願人:日本電子株式会社

    出願番号:特願2005-131106

    出願日:2005年4月28日

    公開番号:特開2006-012782

    公開日:2006年1月12日

  17. 特許名称:高速粒子衝突による衝突誘起解離法を用いた分子構造解析法

    発明者:岩本賢一, 豊田岐聡, 佐藤貴弥

    特許出願人:大阪府立大学,大阪大学,日本電子株式会社

    公開番号:特開2007-33322

    公開日:2007年2月8日

  18. 特許名称:レーザー照射質量分析装置

    発明者:小河潔, 吉田佳一, 島津光三, 瀬藤光利, 新間秀一, 豊田岐聡

    特許出願人:島津製作所, 自然科学研究機構, 大阪大学

    出願番号:特願2005-247134

    出願日:2005年8月29日

    公開番号:特開2007-66533

    公開日:2007年3月15日

  19. 特許名称:イメージング質量分析装置

    発明者:豊田岐聡,石原盛男,粟津邦男,藤井研一,内藤康秀

    特許出願人:光産業創成大学院大学,大阪大学

    出願番号:特願2005-346872

    出願日:2005年11月30日

    公開番号:特開2007-157353

    公開日:2007年6月21日

  20. 特許名称:荷電粒子エネルギー分析装置及び該装置を用いた粒子反応解析装置

    発明者:岩本賢一,豊田岐聡,山口真一,西口克

    特許出願人:大阪府立大学,大阪大学,株式会社島津製作所

    出願番号:特願2006-27998

    出願日:2006年2月6日

    公開番号:特開2007-207696

    公開日:2007年8月16日

  21. 特許名称:質量分析装置

    発明者:豊田岐聡,山口真一,西口克

    特許出願人:大阪大学,株式会社島津製作所

    出願番号:特願2006-197626

    出願日:2006年6月20日

    公開番号:特開2008-27683

    公開日:2008年2月7日

  22. 特許名称:リニアイオントラップ質量分析装置

    発明者:豊田岐聡,岩本賢一,木村健二

    特許出願人:大阪TLO,大阪府立大学,大阪大学

    出願番号:特願2007-19693

    出願日:2007年1月30日

    公開番号:特開2008-186730

    公開日:2008年8月14日

  23. 特許名称:イオン源、およびそれを備える質量分析装置

    発明者:豊田岐聡,青木順,三木伸一

    特許出願人:大阪大学、MSI.TOKYO株式会社

    出願番号:特願2009−080001

    出願日:2009年3月27日

  24. 特許名称:サイクロンセパレータ式質量分析システム

    発明者:三木伸一, 豊田岐聡

    特許出願人:MSI.TOKYO株式会社, 大阪大学

    出願番号:特願2009−138922

    出願日:2009年6月10日

  25. 特許名称:距離測定装置、距離測定方法、距離測定プログラム、およびコンピュータ読み取り可能な記録媒体

    発明者:豊田岐聡,田嶋敏男

    特許出願人:MSI.TOKYO株式会社, 大阪大学

    出願番号:特願2009−235185

    出願日:2009年10月9日

    公開番号:特開2011-080952

    公開日:2011年4月21日

  26. 特許名称:多重周回型飛行時間質量分析方法

    発明者:高橋圭二、豊田岐聡

    特許出願人:MSI.TOKYO株式会社, 大阪大学

    出願番号:特願2010-000330

    出願日:2010年1月5日